Water Treatment Plant (WTP) Maintenance in Bangalore

Reshma Facilities Management operates and maintains apartment water treatment plants in Bangalore. We run the filters, softeners, RO units and chlorination every day, log TDS and hardness, and make sure the water reaching each flat stays within safe limits.

What a WTP does

An apartment water treatment plant cleans incoming water before it goes to the overhead tanks. Depending on your source it will: – Remove sand and suspended particles through pressure sand filters – Remove smell, colour and chlorine taste through activated carbon filters – Reduce hardness through a water softener – Reduce dissolved solids through RO, where fitted – Disinfect through chlorination or UV

Borewell and tanker water in East Bangalore is usually much harder and higher in TDS than Cauvery water, so the WTP in these buildings works a lot harder.

Signs your WTP needs attention

  • White scale on taps, shower heads and tiles
  • Geyser elements failing across several flats
  • Dry skin and hair complaints from residents
  • Soap and detergent not lathering
  • Yellow or brown tint in the water
  • Smell of chlorine or no chlorine at all

The softener is usually the culprit. When its resin bed runs out, water still flows at normal pressure and nothing alarms. Hard water goes straight through, and the first sign is scale in flats months later.

What we do

Task
Frequency

Inlet and outlet TDS

Daily

Inlet and outlet hardness

Daily

Residual chlorine at outlet

Daily

Tanker water TDS on arrival

Every load

Softener regeneration and salt top-up

Based on measured hardness, logged

Sand and carbon filter backwash

To schedule, logged

RO flow and rejection rate

Daily, where fitted

Media and membrane condition check

Periodic

Full water test at an accredited lab

Quarterly or as agreed

Monthly report to the association

Monthly

We regenerate the softener based on actual hardness readings, not a fixed weekly calendar. In tanker-fed buildings, hardness changes with each supplier, so a fixed calendar is wrong most of the time.

Safe TDS and hardness levels

Under IS 10500, the Indian drinking water standard:

Parameter
Acceptable limit
Permissible limit (no alternate source)

Total dissolved solids

500 mg/L

2000 mg/L

Total hardness (as CaCO3)

200 mg/L

600 mg/L

 

A single test after a complaint tells you the water quality that morning. A daily log tells you when it started changing and why.

Repairs and upgrades

We handle media replacement, resin replacement, RO membrane replacement, valve and pump repairs, and dosing system repairs. If a plant is undersized for the building’s current occupancy, we will say so in writing.

Cost of WTP maintenance

Cost depends on plant capacity, whether a full-time operator is needed and whether salt, chemicals and consumables are included.

Frequently asked questions

It depends on the input hardness and daily consumption. Buildings on borewell or tanker water may need regeneration every day or two. The right interval comes from measuring hardness daily.

Only if the incoming TDS is high enough to need it. Many buildings on Cauvery supply need only filtration, softening and chlorination.

Yes. We test each tanker load on arrival and reject loads above the agreed TDS limit where the association approves it.

Scroll to Top